Tel: +86 573 8582 9888
Address: No.398,ChuangQiang Road,XinDai Town,PingHu City,JiaXing City,ZheJiang Province,P.R.China
Materials: ● Conductor: Copper strip T2/C11000 ● Insulation: Nylon Finished: ● Brazed seam ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -40~105℃ ● Flared insulation for easy cable insertion ● Enable universal used with studs/sc...
Materials: ● Conductor: Copper strip T2/C11000 ● Copper sleeve: Copper tubular T2/C11000 ● Insulation: Nylon Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -40~105℃ ● Flared copper sleeve for easy cable insertion ● The ...
Materials: ● Conductor: Copper tubular T2/C11000 ● Insulation: Nylon Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -40~105℃ ● Easy-Entry insulation for easy cable insertion ● Closed end splices to accept a combination o...
Materials: ● Conductor: Spring steel ● Insulation: PP Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -40~105℃ ● Terminal for the connection of two or more conductors by means of screw-type clamping units ● According to ...
Materials: ● Conductor: Copper tubular T2/C11000 ● Insulation: Nylon Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -40~105℃ ● Flared insulation and conductor for easy cable insertion ● Using molding process to strength...
Materials: ● Conductor: Copper tubular T2/C11000 ● Insulation: Nylon Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -40~105℃ ● Easy-Entry insulation for easy cable insertion ● Using molding process to strengthen the adh...
Materials: ● Conductor: Copper tubular T2/C11000 Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Flared copper sleeve for easy cable insertion ● According to UL486 requirements
Materials: ● Conductor: Copper strip T2/C11000 Finished: ● Brazed seam ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Enable universal used with studs/screws to fix on equipments ● Brazed seam on the crimp barrel; Creates a seamless barrel that ...
Materials: ● Conductor: Copper strip T2/C11000 ● Insulation: PVC Finished: ● Brazed seam ● Tin-Plated Standard: ● ROHS3 ● Conductor size accords with DIN46234 Characteristics: ● Heat resistant: -10~75℃ ● Flared insulation for easy cable insertion ● ...
Materials: ● Conductor: Copper strip T2/C11000 ● Insulation: PVC Finished: ● Brazed seam ● Tin-Plated Standard: ● ROHS3 ● Conductor size accords with DIN46234 Characteristics: ● Heat resistant: -10~75℃ ● Enable universal used with studs/screws to fi...
Materials: ● Conductor: Copper strip T2/C11000 ● Copper Sleeve: Copper Tubular T2/C11000 ● Insulation: PVC Finished: ● Tin-Plated ● Standard: ● ROHS3 ● Conductor size accords with DIN46234 Characteristics: ● Heat resistant: -10~75℃ ● Flared copper s...
Materials: ● Conductor: Copper strip T2/C11000 ● Copper Sleeve: Copper Tubular T2/C11000 ● Insulation: PVC Finished: ● Tin-Plated Standard: ● ROHS3 ● Conductor size accords with DIN46234 Characteristics: ● Heat resistant: -10~75℃ ● The Copper sleev...
Materials: ● Conductor: Copper strip T2/C11000 ● Insulation: Nylon Finished: ● Brazed seam ● Tin-Plated Standard: ● ROHS3 ● Conductor size accords with DIN46234 Characteristics: ● Heat resistant: -40~105℃ ● Flared insulation for easy cable insertio...
Materials: ● Conductor: Copper strip T2/C11000 ● Copper sleeve: Copper tubular T2/C11000 ● Insulation: Nylon Finished: ● Tin-Plated Standard: ● ROHS3 ● Conductor size accords with DIN46234 Characteristics: ● Heat resistant: -40~105℃ ● Flared copper...
Materials: ● Conductor: Copper strip T2/C11000 Finished: ● Brazed seam ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Enable universal used with studs/screws to fix on equipments ● Fixing structure with of an open-ended can be installed and remo...
Materials: ● Conductor: Copper strip T2/C11000 ● Insulation: PVC Finished: ● Brazed seam ● Tin-Plated Standard: ● ROHS3 ● Conductor size accords with DIN46234 Characteristics: ● Heat resistant: -10~75℃ ● Flared insulation for easy cable insertion ●...
Materials: ● Conductor: Copper strip T2/C11000 ● Insulation: PVC Finished: ● Brazed seam ● Tin-Plated Standard: ● ROHS3 ● Conductor size accords with DIN46234 Characteristics: ● Heat resistant: -10~75℃ ● Enable universal used with studs/scr...
Materials: ● Conductor: Copper strip T2/C11000 ● Copper sleeve: Copper tubular T2/C11000 ● Insulation: PVC Finished: ● Tin-Plated Standard: ● ROHS3 ● Conductor size accords with DIN46234 Characteristics: ● Heat resistant: -10~75℃ ● Flared c...
Materials: ● Conductor: Copper strip T2/C11000 ● Copper sleeve: Copper tubular T2/C11000 ● Insulation: PVC Finished: ● Tin-Plated Standard: ● ROHS3 ● Conductor size accords with DIN46234 Characteristics: ● Heat resistant: -10~75℃ ● The copp...
Materials: ● Conductor: Copper strip T2/C11000 ● Insulation: Nylon Finished: ● Brazed Seam ● Tin-Plated Standard: ● ROHS3 ● Conductor size accords with DIN46234 Characteristics: ● Heat resistant: -40~105℃ ● Flared insulation for easy cable ...
Materials: ● Conductor: Copper strip T2/C11000 ● Copper sleeve: Copper tubular T2/C11000 ● Insulation: Nylon Finished: ● Tin-Plated Standard: ● ROHS3 ● Conductor size accords with DIN46234 Characteristics: ● Heat resistant: -40~105℃ ● Flare...
Materials: ● Conductor: Copper strip T2/C11000 Finished: ● Brazed seam ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Fit all popular pin-types (European) terminal blocks ● Allow for quick wire connects and disconnects from components wher...
Materials: ● Conductor: Copper strip T2/C11000 ● Insulation: PVC Finished: ● Brazed seam ● Tin-Plated Standard: ● ROHS3 ● Conductor size accords with DIN46230 Characteristics: ● Heat resistant: -10~75℃ ● Flared insulation for easy cable ins...
Materials: ● Conductor: Copper strip T2/C11000 ● Insulation: PVC Finished: ● Brazed seam ● Tin-Plated Standard: ● ROHS3 ● Conductor size accords with DIN46230 Characteristics: ● Heat resistant: -10~75℃ ● Fit all popular pin-types (European)...
Materials: ● Conductor: Copper strip T2/C11000 ● Insulation: PVC Finished: ● Tin-Plated Standard: ● ROHS3 ● Conductor size accords with DIN46230 Characteristics: ● Heat resistant: -10~75℃ ● Flared insulation for easy cable insertion ● Fit a...
Materials: ● Conductor: Copper strip T2/C11000 ● Insulation: PVC Finished: ● Tin-Plated Standard: ● ROHS3 ● Conductor size accords with DIN46230 Characteristics: ● Heat resistant: -10~75℃ ● Fit all popular pin-types (European) terminal block...
Materials: ● Conductor: Copper strip T2/C11000 ● Copper sleeve: Copper tubular T2/C11000 ● Insulation: PVC Finished: ● Tin-Plated Standard: ● ROHS3 ● Conductor size accords with DIN46230 Characteristics: ● Heat resistant: -10~75℃ ● Flared c...
Materials: ● Conductor: Copper strip T2/C11000 ● Copper sleeve: Copper tubular T2/C11000 ● Insulation: PVC Finished: ● Tin-Plated Standard: ● ROHS3 ● Conductor size accords with DIN46230 Characteristics: ● Heat resistant: -10~75℃ ● The copp...
Materials: ● Conductor: Copper strip T2/C11000 ● Insulation: Nylon Finished: ● Brazed seam ● Tin-Plated Standard: ● ROHS3 ● Conductor size accords with DIN46230 Characteristics: ● Heat resistant: -40~105℃ ● Flared insulation for easy cable ...
Materials: ● Conductor: Copper strip T2/C11000 ● Copper sleeve: Copper tubular T2/C11000 ● Insulation: Nylon Finished: ● Tin-Plate Standard: ● ROHS3 ● Conductor size accords with DIN46230 Characteristics: ● Heat resistant: -40~105℃ ● Flare...
Materials: ● Conductor: Copper Tubular T2/C11000 ● Insulation: Dual wall heat-shrinkable tube Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -45~125℃ ● Flared insulation for easy cable insertion ● One or more conductors...
Materials: ● Conductor: Copper strip T2/C11000 ● Insulation: Dual wall heat-shrinkable tube Finished: ● Brazed seam ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -45~125℃ ● Excellent insulation clarity: Easy to see wire conducto...
Materials: ● Conductor: Copper strip T2/C11000 ● Copper sleeve: Copper tubular T2/C11000 ● Insulation: Dual wall heat-shrinkable tube Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -45~125℃ ● Flared copper sleeve for ea...
Materials: ● Conductor: Copper strip T2/C11000 ● Insulation: Dual wall heat-shrinkable tube Finished: ● Brazed seam ● Tin-Plated Standard: ● ROHS3 ● Conductor size accords with DIN46234 Characteristics: ● Heat resistant: -45~125℃ ● Excellent insula...
Materials: ● Conductor: Copper strip T2/C11000 ● Copper sleeve: Copper tubular T2/C11000 ● Insulation: Dual wall heat-shrinkable tube Finished: ● Tin-Plated Standard: ● ROHS3 ● Conductor size accords with DIN46234 Characteristics: ● Heat resistant:...
Materials: ● Conductor: Copper strip T2/C11000 ● Insulation: Dual wall heat-shrinkable tube Finished: ● Brazed seam ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -45~125℃ ● Excellent insulation clarity: Easy to see wire conducto...
Materials: ● Conductor: Copper strip T2/C11000 ● Copper sleeve: Copper tubular T2/C11000 ● Insulation: Dual wall heat-shrinkable tube Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -45~125℃ ● Flared copper sleeve for ea...
Materials: ● Conductor: Copper strip T2/C11000 ● Insulation: Dual wall heat-shrinkable tube Finished: ● Brazed seam ● Tin-Plated Standard: ● ROHS3 ● Conductor size accords with DIN46234 Characteristics: ● Heat resistant: -45~125℃ ● Excellent insula...
Materials: ● Conductor: Copper strip T2/C11000 ● Copper sleeve: Copper tubular T2/C11000 ● Insulation: Dual wall heat-shrinkable tube Finished: ● Tin-Plated Standard: ● ROHS3 ● Conductor size accords with DIN46234 Characteristics: ● Heat resistant:...
Materials: ● Conductor: Brass strip H62/C28000| ● Copper sleeve: Copper tubular T2/C11000 ● Insulation: Dual wall heat-shrinkable tube Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -45~125℃ ● Flared copper sleeve for e...
Materials: ● Conductor: Brass strip H62/C28000 ● Inner insulation: Nylon ● Outer insulation: Dual wall Heat-shrinkable tube Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -45~125℃ ● Flared insulation for easy cable inse...
Materials: ● Conductor: Brass strip H62/C28000 ● Copper sleeve: Copper tubular T2/C11000 ● Insulation: Dual wall heat-shrinkable tube Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -45~125℃ ● Flared copper sleeve for eas...
Materials: ● Conductor: Brass strip H62/C28000 ● Copper sleeve: Copper tubular T2/C11000 ● Insulation: Dual wall heat-shrinkable tube Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -45~125℃ ● Flared copper sleeve for ea...
Materials: ● Conductor: Brass strip H62/C28000 ● Inner insulation: Nylon ● Outer insulation: Dual wall Heat-shrinkable tube Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -45~125℃ ● Flared insulation for easy cable inse...
Materials: ● Conductor: Brass strip H62/C28000 ● Copper sleeve: Copper tubular T2/C11000 ● Insulation: Dual wall heat-shrinkable tube Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -45~125℃ ● Flared copper sleeve for ea...
Materials: ● Conductor: Brass strip H62/C28000 ● Copper sleeve: Copper tubular T2/C11000 ● Insulation: Dual wall heat-shrinkable tube Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -45~125℃ ● Flared copper sleeve for ea...
Materials: ● Conductor: Brass strip H62/C28000 ● Copper sleeve: Copper tubular T2/C11000 ● Insulation: PVC Finished: ● Tin-Plated Standard : ● ROHS3 Characteristics: ● Heat resistant: -10~75℃ ● Flared copper sleeve for easy cable insertion ● The co...
Materials : ● Conductor: Brass strip H62/C28000 ● Copper sleeve: Copper tubular T2/C11000 ● Insulation: PVC Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics : ● Heat resistant: -10~75℃ ● The copper sleeve protection terminal and the cable a...
Materials: ● Conductor: Brass strip H62/C28000 ● Copper sleeve: Copper tubular T2/C11000 ● Insulation: Nylon Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -40~105℃ ● Flared copper sleeve for easy cable insertion ● The ...
Materials: ● Conductor: Brass strip H62/C28000 ● Insulation: PVC Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -10~75℃ ● Low insertion force to mate easily with UL-compliant male tabs while maintaining a high retention ...
Materials: ● Conductor: Brass strip H62/C28000 ● Copper sleeve: Copper tubular T2/C11000 ● Insulation: PVC Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -10~75℃ ● Flared copper sleeve for easy cable insertion ● The cop...
Materials: ● Conductor: Brass strip H62/C28000 ● Copper sleeve: Copper tubular T2/C11000 ● Insulation: PVC Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -10~75℃ ● The copper sleeve protection terminal and the cable are...
Materials: ● Conductor: Brass strip H62/C28000 ● Insulation: Nylon Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -40~105℃ ● Flared insulation for easy cable insertion ● Low insertion force to mate easily with UL-compli...
Materials: ● Conductor: Brass strip H62/C28000 ● Insulation: PVC Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -10~75℃ ● Low insertion force to mate easily with UL-compliant male tabs while maintaining a high retention...
Materials: ● Conductor: Brass strip H62/C28000 ● Copper sleeve: Copper tubular T2/C11000 ● Insulation: PVC Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -10~75℃ ● Flared copper sleeve for easy cable insertion ● The cop...
Materials: ● Conductor: Brass strip H62/C28000 ● Copper sleeve: Copper tubular T2/C11000 ● Insulation: PVC Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -10~75℃ ● The copper sleeve protection terminal and the cable are...
Materials: ● Conductor: Brass strip H62/C28000 ● Copper sleeve: Copper tubular T2/C11000 ● Insulation: Nylon Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -40~105℃ ● Flared copper sleeve for easy cable insertion ● The ...
Materials: ● Conductor: Brass strip H62/C28000 ● Insulation: PVC Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -10~75℃ ● Flared-barrel entry for easy wire insertion ● According to UL310 requirements
Materials: ● Conductor: Brass strip H62/C28000 ● Insulation: Nylon Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -40~105℃ ● Flared insulation for easy cable insertion ● Flared-barrel entry for easy wire insertion ● Ful...
Materials: ● Conductor: Brass strip H62/C28000 ● Copper sleeve: Copper tubular T2/C11000 ● Insulation: PVC Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -10~75℃ ● Flared copper sleeve for easy cable insertion ● The cop...
Materials: ● Conductor: Brass strip H62/C28000 ● Copper sleeve: Copper tubular T2/C11000 ● Insulation: PVC Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -10~75℃ ● The copper sleeve protection terminal and the cable are...
Materials: ● Conductor: Brass strip H62/C28000 ● Copper sleeve: Copper tubular T2/C11000 ● Insulation: Nylon Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -40~105℃ ● Flared copper sleeve for easy cable insertion ● The ...
Materials: ● Conductor: Brass strip H62/C28000 ● Insulation: PVC Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -10~75℃ ● Low insertion force to mate easily with UL-compliant male tabs while maintaining a high retention...
Materials: ● Conductor: Brass strip H62/C28000 ● Copper sleeve: Copper tubular T2/C11000 ● Insulation: Nylon Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -40~105℃ ● Flared copper sleeve for easy cable insertion ● The...
Materials: ● Conductor: Brass strip H62/C28000 ● Copper sleeve: Copper tubular T2/C11000 ● Insulation: PVC Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -10~75℃ ● Flared copper sleeve for easy cable insertion ● The cop...
Materials: ● Conductor: Brass strip H62/C28000 ● Copper sleeve: Copper tubular T2/C11000 ● Insulation: PVC Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -10~75℃ ● The copper sleeve protection terminal and the cable are...
Materials: ● Conductor: Brass strip H62/C28000 ● Copper sleeve: Copper tubular T2/C11000 ● Insulation: Nylon Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -40~105℃ ● Flared copper sleeve for easy cable insertion ● The ...
Materials: ● Conductor: Brass strip H62/C28000 ● Insulation: PVC Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -10~75℃ ● Flared-barrel entry for easy wire insertion ● According to UL486 requirements
Materials: ● Conductor: Brass strip H62/C28000 ● Copper sleeve: Copper tubular T2/C11000 ● Insulation: Nylon Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -40~105℃ ● Flared copper sleeve for easy cable insertion ● The ...
Materials: ● Conductor: Brass strip H62/C28000 ● Copper sleeve: Copper tubular T2/C11000 ● Insulation: PVC Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -10~75℃ ● Flared copper sleeve for easy cable insertion ● The cop...
Materials: ● Conductor: Brass strip H62/C28000 ● Copper sleeve: Copper tubular T2/C11000 ● Insulation: PVC Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -10~75℃ ● The copper sleeve protection terminal and the cable ar...
Materials: ● Conductor: Brass strip H62/C28000 ● Copper sleeve: Copper tubular T2/C11000 ● Insulation: Nylon Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -40~105℃ ● Flared copper sleeve for easy cable insertion ● The...
Materials: ● Conductor: Brass strip H62/C28000 ● Insulation: PVC Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -10~75℃ ● Low insertion force to mate easily with UL-compliant male tabs while maintaining a high retention...
Materials: ● Conductor: Brass strip H62/C28000 ● Insulation: Nylon Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -40~105℃ ● Flared insulation for easy cable insertion ● Low insertion force to mate easily with UL-compli...
Materials: ● Conductor: Brass strip H62/C28000 Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Low insertion force to mate easily with UL-compliant male tabs while maintaining a high retention ● Right-angle structure to be mated easily ...
Materials: ● Conductor: Brass strip H62/C28000 ● Insulation: Nylon Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -40~105℃ ● Easy-Entry insulation for easy cable insertion ● Use insulation displacement technology to mak...
Materials: ● Conductor: Brass strip H62/C28000 ● Insulation: Nylon Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -40~105℃ ● Easy-Entry insulation for easy cable insertion ● Use insulation displacement technology to mak...
Materials: ● Conductor: Copper strip T2/C11000 ● Copper sleeve: Copper tubular T2/C11000 ● Insulation: PVC Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -10~75℃ ● Flared copper sleeve for easy cable insertion ● The cop...
Materials: ● Conductor: Brass stripT2/C11000 ● Insulation: PVC Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -10~75℃ ● The conductor is made of the stamping barrel type ● One or more conductors of varying gauges can be...
Materials: ● Conductor: Copper strip T2/C11000 ● Insulation: PVC Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -10~75℃ ● The conductor is made of the stamping barrel type ● One or more conductors of varying gauges can ...
Materials: ● Conductor: Copper tubular T2/C11000 ● Insulation: PVC Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -10~75℃ ● Seamless tube of conductor ● One or more conductors of varying gauges can be laid on top of one...
Materials: ● Conductor: Brass strip H62/C26800 ● Insulation: Nylon Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -40~105℃ ● The conductor is made of the stamping barrel type ● One or more conductors of varying gauges c...
Materials: ● Conductor: Copper strip T2/C11000 ● Insulation: Nylon Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -40~105℃ ● The conductor is made of the stamping barrel type ● One or more conductors of varying gauges c...
Materials: ● Conductor: Copper tubular T2/C11000 ● Insulation: Nylon Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -40~105℃ ● Seamless tube of conductor ● One or more conductors of varying gauges can be laid on top of ...
Materials: ● Copper tubular T2/C11000 Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics: ● One or more conductors of varying gauges can be laid on top of one another and crimped in a short space ● WIRE-STOP structure is conducive to insertio...
Materials: ● Copper tubular T2/C11000 Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics: ● One or more conductors of varying gauges can be laid on top of one another and crimped in a short space ● WIRE-STOP structure is conducive to insertio...
Materials: ● Copper tubular T2/C11000 Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics: ● One or more conductors of varying gauges can be laid on top of one another and crimped in a short space ● WIRE-STOP structure is conducive to insertio...
Materials: ● Copper tubular T2/C11000 Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics: ● One or more conductors of varying gauges can be laid on top of one another and crimped in a short space ● WIRE-STOP structure is conducive to insertio...
Materials: ● Conductor: Copper strip T2/C11000 Finished: ● Brazed seam ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Enable universal used with studs/screws to fix on equipments ● Brazed seam on the crimp barrel; Creates a seamless barrel that ...
Materials: ● Conductor: Copper strip T2/C11000 ● Insulation: PVC Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -10~75℃ ● Flared insulation for easy cable insertion ● Enable universal used with studs/screws to fix on eq...
Materials: ● Conductor: Copper strip T2/C11000 ● Insulation: PVC Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -10~75℃ ● Enable universal used with studs/screws to fix on equipments ● According to UL486 requirements
Materials: ● Conductor: Copper strip T2/C11000 ● Insulation: PVC Finished: ● Brazed seam ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -10~75℃ ● Enable universal used with studs/screws to fix on equipments ● Brazed seam on the c...
Materials: ● Conductor: Copper strip T2/C11000 ● Copper sleeve: Copper tubular T2/C11000 ● Insulation: PVC Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -10~75℃ ● Flared copper sleeve for easy cable insertion ● The cop...
Materials: ● Conductor: Copper strip T2/C11000 ● Copper sleeve: Copper tubular T2/C11000 ● Insulation: PVC Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -10~75℃ ● The copper sleeve protection terminal and the cable are...
Materials: ● Conductor: Copper strip T2/C11000 ● Insulation: Nylon Finished: ● Brazed seam ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -40~105℃ ● Flared insulation for easy cable insertion ● Enable universal used with studs/sc...
Materials: ● Conductor: Copper strip T2/C11000 ● Copper sleeve: Copper tubular T2/C11000 ● Insulation: Nylon Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -40~105℃ ● Flared copper sleeve for easy cable insertion ● The ...
Materials: ● Conductor: Copper strip T2/C11000 Finished: ● Brazed seam ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Enable universal used with studs/screws to fix on equipments ● Fixing structure with of an open-ended can be installed and remo...
Materials: ● Conductor: Copper strip T2/C11000 ● Insulation: PVC Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -10~75℃ ● Flared insulation for easy cable insertion ● Enable universal used with studs/screws to fix on eq...
Materials: ● Conductor: Copper strip T2/C11000 ● Insulation: PVC Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -10~75℃ ● Enable universal used with studs/screws to fix on equipments ● Fixing structure with of an open-e...
Materials: ● Conductor: Copper strip T2/C11000 ● Insulation: PVC Finished: ● Brazed seam ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -10~75℃ ● Enable universal used with studs/screws to fix on equipments ● Fixing structure wit...
Materials: ● Conductor: Copper strip T2/C11000 ● Copper sleeve: Copper tubular T2/C11000 Insulation: PVC ● Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -10~75℃ ● Flared copper sleeve for easy cable insertion ● The cop...
Materials: ● Conductor: Copper strip T2/C11000 ● Copper sleeve: Copper tubular T2/C11000 ● Insulation: PVC Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -10~75℃ ● The copper sleeve protection terminal and the cable are...
Materials: ● Conductor: Copper strip T2/C11000 ● Insulation: Nylon Finished: ● Brazed Seam ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -40~105℃ ● Flared insulation for easy cable insertion ● Enable universal used with studs/sc...
Materials: ● Conductor: Copper strip T2/C11000 ● Copper sleeve: Copper tubular T2/C11000 ● Insulation: Nylon Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -40~105℃ ● Flared copper sleeve for easy cable insertion ● The ...
Materials: ● Conductor: Copper strip T2/C11000 Finished: ● Brazed seam ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Fit all popular pin-types (European) terminal blocks or related similar equipment ● Allow for quick wire connects and disconnec...
Materials: ● Conductor: Copper strip T2/C11000 ● Insulation: PVC Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -10~75℃ ● Fit all popular pin-types (European) terminal blocks or related similar equipment ● Allow for qui...
Materials: ● Conductor: Copper strip T2/C11000 ● Insulation: PVC Finished: ● Brazed seam ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -10~75℃ ● Fit all popular pin-types (European) terminal blocks or related similar equipment ●...
Materials: ● Conductor: Copper strip T2/C11000 ● Copper sleeve: Copper tubular T2/C11000 ● Insulation: PVC Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -10~75℃ ● Flared copper sleeve for easy cable insertion ● The c...
Materials: ● Conductor: Copper strip T2/C11000 ● Copper sleeve: Copper tubular T2/C11000 ● Insulation: PVC Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -10~75℃ ● The copper sleeve protection terminal and the cable are...
Materials: ● Conductor: Copper strip T2/C11000 ● Insulation: Nylon Finished: ● Brazed seam ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -40~105℃ ● Flared insulation for easy cable insertion ● Fit all popular pin-types (Europea...
Materials: ● Conductor: Copper strip T2/C11000 ● Copper sleeve: Copper tubular T2/C11000 ● Insulation: Nylon Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -40~105℃ ● Flared copper sleeve for easy cable insertion ● The ...
Materials: ● Conductor: Copper strip T2/C11000 ● Insulation: PVC Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -10~75℃ ● Enable universal used with studs/screws to fix on equipments ● The flanged ends reduce possibilit...
Materials: ● Conductor: Copper strip T2/C11000 ● Insulation: PVC Finished: ● Brazed seam ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -10~75℃ ● Enable universal used with studs/screws to fix on equipments ● The flanged ends red...
Materials: ● Conductor: Copper strip T2/C11000 ● Copper sleeve: Copper tubular T2/C11000 ● Insulation: PVC Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -10~75℃ ● Flared copper sleeve for easy cable insertion ● The Copp...
Materials: ● Conductor: Copper strip T2/C11000 ● Copper sleeve: Copper tubular T2/C11000 ● Insulation: PVC Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -10~75℃ ● The Copper sleeve protection terminal and the cable are...
Materials: ● Conductor: Copper strip T2/C11000 ● Insulation: Nylon Finished: ● Brazed seam ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -40~105℃ ● Flared insulation for easy cable insertion ● Enable universal used with studs/sc...
Materials: ● Conductor: Copper strip T2/C11000 ● Copper sleeve: Copper tubular T2/C11000 ● Insulation: Nylon Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -40~105℃ ● Flared copper sleeve for easy cable insertion ● The ...
Materials: ● Conductor: Copper strip T2/C11000 ● Insulation: PVC Finished: ● Brazed seam ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -10~75℃ ● Enable use with M3.5/M4/M5 studs/screws to fix on equipment ● Brazed seam on the cr...
Materials: ● Conductor: Copper strip T2/C11000 ● Copper sleeve: Copper tubular T2/C11000 ● Insulation: PVC Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -10~75℃ ● Flared copper sleeve for easy cable insertion ● The cop...
Materials: ● Conductor: Copper strip T2/C11000 ● Insulation: Nylon Finished: ● Brazed seam ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -40~105℃ ● Flared insulation for easy cable insertion ● Enable use with M3.5/M4/M5 studs/sc...
Materials: ● Conductor: Copper strip T2/C11000 ● Copper sleeve: Copper tubular T2/C11000 ● Insulation: Nylon Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -40~105℃ ● Flared copper sleeve for easy cable insertion ● The co...
Materials: ● Conductor: Copper strip T2/C11000 ● Insulation: PVC Finished: ● Brazed seam ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -10~75℃ ● Enable universal used with studs/screws to fix on equipments ● Fixing structure wit...
Materials: ● Conductor: Copper strip T2/C11000 ● Copper sleeve: Copper tubular T2/C11000 ● Insulation: PVC Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -10~75℃ ● Flared copper sleeve for easy cable insertion ● The cop...
Materials: ● Conductor: Copper strip T2/C11000 ● Insulation: Nylon Finished: ● Brazed seam ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -40~105℃ ● Flared insulation for easy cable insertion ● Enable universal used with studs/sc...
Materials: ● Conductor: Copper strip T2/C11000 ● Copper sleeve: Copper tubular T2/C11000 ● Insulation: Nylon Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -40~105℃ ● Flared copper sleeve for easy cable insertion ● The ...
Materials: Conductor: Copper strip T2/C11000 Insulation: PVC Finished: Brazed seam Tin-Plated Standard: ROHS3 Characteristics: Heat resistant: -10~75℃ Enable universal used with studs/screws to fix on equipments Fixing structure with an open-ended ...
Materials: ● Conductor: Copper strip T2/C11000 ● Copper sleeve: Copper tubular T2/C11000 ● Insulation: PVC Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -10~75℃ ● Flared copper sleeve for easy cable insertion ● The Cop...
Materials: ● Conductor: Copper strip T2/C11000 ● Insulation: Nylon Finished: ● Brazed seam ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -40~105℃ ● Flared insulation for easy cable insertion ● Enable universal used with studs/sc...
Materials: ● Conductor: Copper strip T2/C11000 ● Copper sleeve: Copper tubular T2/C11000 ● Insulation: Nylon Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -40~105℃ ● Flared copper sleeve for easy cable insertion\ ● The...
Materials: ● Conductor: Copper strip T2/C11000 ● Insulation: PVC Finished: ● Brazed seam ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -10~75℃ ● Enable universal used with studs/screws to fix on equipments ● Fixing structure wi...
Materials: ● Conductor: Copper strip T2/C11000 ● Copper sleeve: Copper tubular T2/C11000 ● Insulation: PVC Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -10~75℃ ● Flared copper sleeve for easy cable insertion ● The Copp...
Materials: ● Conductor: Copper strip T2/C11000 ● Insulation: Nylon Finished: ● Brazed seam ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -40~105℃ ● Flared insulation for easy cable insertion ● Enable universal used with studs/sc...
Materials: ● Conductor: Copper strip T2/C11000 ● Copper sleeve: Copper tubular T2/C11000 ● Insulation: Nylon Finished: ● Tin-Plated Standard: ROHS3 Characteristics: ● Heat resistant: -40~105℃ ● Flared copper sleeve for easy cable insertion ● The Co...
Materials: ● Conductor: Copper strip T2/C11000 ● Insulation: PVC Finished: ● Brazed seam ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -10~75℃ ● Enable universal used with studs/screws to fix on equipments ● Fixing structure wi...
Materials: ● Conductor: Copper strip T2/C11000 ● Copper sleeve: Copper tubular T2/C11000 ● Insulation: PVC Finished: ● Tin-Plated ● Standard: ● ROHS3 Characteristics: ● Heat resistant: -10~75℃ ● Flared copper sleeve for easy cable insertion ● The ...
Materials: ● Conductor: Copper strip T2/C11000 ● Insulation: Nylon Finished: ● Brazed seam ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -40~105℃ ● Flared insulation for easy cable insertion ● Enable universal used with studs/sc...
Materials: ● Conductor: Copper strip T2/C11000 ● Copper sleeve: Copper tubular T2/C11000 ● Insulation: Nylon Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -40~105℃ ● Flared copper sleeve for easy cable insertion ● The ...
Materials: ● Conductor: Copper tubular T2/C11000 ● Insulation: Nylon Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -40~105℃ ● Easy-Entry insulation for easy cable insertion ● Closed end splices to accept a combination o...
Materials: ● Conductor: Spring steel ● Insulation: PP Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -40~105℃ ● Terminal for the connection of two or more conductors by means of screw-type clamping units ● According to ...
Materials: ● Conductor: Copper tubular T2/C11000 ● Insulation: Nylon Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -40~105℃ ● Flared insulation and conductor for easy cable insertion ● Using molding process to strength...
Materials: ● Conductor: Copper tubular T2/C11000 ● Insulation: Nylon Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Heat resistant: -40~105℃ ● Easy-Entry insulation for easy cable insertion ● Using molding process to strengthen the adh...
Materials: ● Conductor: Copper tubular T2/C11000 Finished: ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Flared copper sleeve for easy cable insertion ● According to UL486 requirements
Materials: ● Conductor: Copper strip T2/C11000 Finished: ● Brazed seam ● Tin-Plated Standard: ● ROHS3 Characteristics: ● Enable universal used with studs/screws to fix on equipments ● Brazed seam on the crimp barrel; Creates a seamless barrel that ...